设为首页
加入收藏
联系我们
Email-Alert
 

    首页 | 杂志介绍 | 编委成员 | 投稿指南 | 订阅指南 | 过刊浏览 | 论著模板 | 综述模板 | 出版伦理声明 | 帮助

 
危昔均,汤启宇,燕铁斌,胡晓翎.慢性期卒中患者上肢机器人训练前后重复测量试验中三个评估量表的响应度[J].中国康复医学杂志,2012,27(11):1002~1005
慢性期卒中患者上肢机器人训练前后重复测量试验中三个评估量表的响应度    点此下载全文
危昔均  汤启宇  燕铁斌  胡晓翎
中山大学孙逸仙纪念医院康复医学科,广州,510120
基金项目:香港特别行政区大学教育资助委员会研究基金(PolyU 5292/08E);广东省科技计划项目(2010A040302002)
DOI:
摘要点击次数: 2369
全文下载次数: 3365
摘要:
      摘要 目的:评价Fugl-Meyer运动功能评分上肢部分(FMA-UE)、运动功能状态量表(MSS)、上肢运动研究量表(ARAT)在重复测量慢性期卒中患者上肢功能表现方面的响应度。 方法:27例慢性期卒中患者被随机分到实验组(15例)进行PolyJbot上肢机器人腕关节主动-辅助屈伸训练,对照组(12例)进行Cybex上肢机器人腕关节被动屈伸训练。被设盲的评估者对参与实验的患者分别在实验前进行两次,实验后进行一次身体结构功能及活动功能评估。主要使用的评估量表有FMA-UE、MSS、ARAT、肘和腕关节屈肌张力(MAS)、功能独立性评定(FIM)。采用重复测量方差分析检验治疗前后的治疗效果,Guyatt's响应度指数(GRI)测量各评估量表的响应度。 结果:Guyyatt响应度指数显示治疗组患者的FMA-UE、FMA-UE(SE)、MSS的响应度明显大于其他量表,对照组患者的FMA-UE(SE)、MSS、MAS(W)显示较大的响应度。 结论:FMA-UE和MSS在慢性期卒中上肢中度瘫痪患者,重复测试的上肢机器人腕关节训练相关试验中显示出较高的响应度。
关键词:卒中  机器人  评估量表  响应度
The responsiveness of three assessments in repeatedly measuring upper extremity performance of chronic stroke survivors in robotic training    Download Fulltext
Department of Rehabilitation Medicine, Sun Yat-sen Memorial Hospital, Sun Yat-sen University,510120
Fund Project:
Abstract:
      Abstract Objective To investigate the responsiveness of Fugl-Meyer assessment upper extremity section(FMA-UE), motor status scale(MSS), action research arm test(ARAT) in repeatedly measuring upper extremity performance of chronic stroke survivors who were recited for upper extremity robotic training. Method: Twenty-seven stroke survivors were signed to either experimental group(n=15) for PolyJbot training(active-assisted wrist extension and flexion) or control group(n=12) for Cybex training(passive wrist extension and flexion).Blinded assessor evaluated the body function and activities of participants with FMA-UE,MSS,ARAT,and functional independent measure(FIM) two times pre intervention and one time post intervention.Repeated measures analysis of variance(Repeated measures ANOVA) was employed for testing the significance of changes pre and post training,and Guyyatt's responsiveness index(GRI) was used for measuring the responsiveness of the assessments. Result: GRI showed that FMA-UE, FMA-UE(SE), and MSS had relative high responsiveness in experimental group, FMA-UE(SE), MSS, MAS(W) had more sensitive responsiveness in control group. Conclusion: FMA-UE and MSS had higher responsiveness in repeatedly measuring upper extremity performance of chronic stroke survivors with moderate impaired upper limb function in robotic assisted wrist training study.
Keywords:stroke  robotic  assessment  responsiveness
查看全文  查看/发表评论

您是本站第 40813112 位访问者

版权所有:中国康复医学会
主管单位:中国科学技术协会 主办单位:中国康复医学会
地址:北京市朝阳区樱花园东街,中日友好医院内   邮政编码:100029   电话:010-64218095   

本系统由北京勤云科技发展有限公司设计
京ICP备18060696号-2

京公网安备 11010502038612号