目的:评估两点辨别测试(TPD)、点对点测试(PTP)和两点距离估算(TPE)三种测试在正常人和慢性腰痛人群(CLBP)中的重测信度和测试者间信度。
方法:筛选30例正常人和30例CLBP患者,由两名物理治疗师分别对60例受试者进行TPD、PTP和TPE三种测试评估,测试者间测试间隔时间为10min,其中一人在24h后重复上述测试,通过组内相关系数(ICC)评估重测信度和测试者间信度。
结果:正常组中,TPD、PTP和TPE三种测试左右两侧的重测信度(ICC:0.78—0.90)和测试者间信度 (ICC:0.75—0.87)均良好。腰痛组中,TPD、PTP和TPE三种测试疼痛侧与非疼痛侧的重测信度(ICC:0.75—0.90)良好,测试者间信度(ICC:0.72—0.87)中等到良好。
结论:三种评估方法在正常人和慢性腰痛人群中的信度可靠,足以在未来评估两种人群的触觉敏锐度。 |
关键词:两点辨别测试 点对点测试 两点距离估算 重测信度 测试者间信度 |
Reliability of sensory test in individuals with chronic low back pain Download Fulltext |
|
Sports Medicine Rehabilitation Center, Shanghai University of Sport, Shanghai, 200438 |
Fund Project: |
Abstract: |
Abstract
Objective:To assess the intra- and inter-tester reliability of two-point discrimination (TPD), point-to-point test (PTP) and two-point estimation (TPE) in healthy subjects and subjects with chronic low back pain (CLBP) respectively.
Method:Thirty healthy people and 30 patients were recruited with CLBP and divided into a healthy group and a CLBP group,equally. Subjects were assessed by two testers within the same day (10 min interval), and one of the testers repeated the assessment program 24 h later. The intraclass correlation coefficient (ICC) was used to assess the reliability.
Result:In the healthy group, the intra-tester reliability of three measurements on both sides of L5 was good (ICC: 0.78—0.90), while the inter-tester reliability of three measurements on both sides of L5 was good (ICC: 0.75—0.87). In the CLBP group, the intra-tester reliability of three measurements on the pain and non-pain sides was good (ICC: 0.75—0.90), while the inter- tester reliability of three measurements on the pain and non-pain sides was moderate to good (ICC: 0.72—0.87).
Conclusion:The reliability of the three assessment methods in healthy people and patients with CLBP is reliable enough to assess the tactile acuity of both groups in the future. |
Keywords:two-point discrimination point-to-point test two-point estimation intra-tester reliability inter-tester reliability |
|
查看全文 查看/发表评论 |